Specification

Material - Aluminium, Steel

Finish - PPC, Pre-paint, Anodised, Corten, Rimex

Thickness - 2 / 3mm

Panel size - 1480 x 3850mm max

Horizontal joint - 20mm

Fixings - Self drill mechanical fixings

Rail centres - 600mm max

Install method - 1st & 2nd fix layout

CWCT tested with Hilti-EurofoxFor facades where an element of adjustment is required an Eltherington through-fix rainscreen cladding system is the best choice.

Our through fix system offers an adjustable void depth and is therefore able to accommodate a range of insulation thicknesses, whilst overcoming any irregularities in the substrate.

That makes the rainscreen cladding solution ideal where the variances in quality of infill material on existing buildings dictate that fixings can only be secured at certain points across the facade, for example, at floor slabs.

Eltherington through-fix systems are designed so that the fixings are minimally visible across the facade, being masked by the shadow-lines between the panels.

From a distance, this maintains the sheer, architectural appearance of the facade.


Specification Details for A2 Fire Rated Aluminium Cladding - TFS1 (CWCT Tested) (Rainscreen Cladding)

Eltherington Group
Eltherington Group
Hull
United Kingdom
HU9 5QD
P: 07867424063

A2 Fire Rated Aluminium Cladding - TFS1 (CWCT Tested)

TFS1 - 5.4 [2mm]
• Max Length Tested: 2850 mm
•最大宽度测试:580 mm
• Thickness: 2 mm
• Weight per m2: 5.4 Kg/m2
• Finish(es): Anodised, Brushed, Perforated, Powder coated
• Material: ACM A2, Aluminium, Apolic A1 ACM, Metal, Steel
• Certifications: CWCT
• Reaction to fire: A2
• Standards: ISO 14001, ISO 18001, ISO 9001
• Min Panel Cost £: 60
• Min Support Rail Cost £: 22
• Uniclass Code: Ss_25_20_70
• Uniclass Name: Rainscreen cladding systems

TFS1 - 7.4 [2mm]
• Max Length Tested: 3850 mm
•最大宽度测试:1450 mm
• Thickness: 2 mm
• Weight per m2: 7.4 Kg/m2
• Finish(es): Anodised, Brushed, Perforated, Powder coated
• Material: ACM A2, Aluminium, Apolic A1 ACM, Metal, Steel
• Certifications: CWCT
• Reaction to fire: B
• Standards: ISO 14001, ISO 18001, ISO 9001
• Min Panel Cost £: 65
• Min Support Rail Cost £: 22
• Uniclass Code: Ss_25_20_70
• Uniclass Name: Rainscreen cladding systems

TFS1 - 10.1 [3mm]
• Max Length Tested: 4010 mm
•最大宽度测试:998 mm
• Thickness: 3 mm
• Weight per m2: 10.1 Kg/m2
• Uniclass Code: Ss_25_20_70
• Uniclass Name: Rainscreen cladding systems
• Certifications: CWCT
• Reaction to fire: B
• Standards: ISO 14001, ISO 18001, ISO 9001
• Min Panel Cost £: 75
• Min Support Rail Cost £: 22
• Finish(es): Anodised, Brushed, Perforated, Powder coated

TFS1 - 10.8 [4mm]
• Max Length Tested: 2380 mm
•最大宽度测试:1280 mm
• Thickness: 4 mm
• Weight per m2: 10.8 Kg/m2
• Uniclass Code: Ss_25_20_70
• Uniclass Name: Rainscreen cladding systems
• Certifications: CWCT
• Reaction to fire: A2
• Standards: ISO 14001, ISO 18001, ISO 9001
• Min Panel Cost £: 80
• Min Support Rail Cost £: 22
• Finish(es): Anodised, Brushed, Perforated, Powder coated

Please note that these product properties are not a replacement for the manufacturer's literature and it is always recommended thatEltherington Groupis consulted before specifying.

File Downloads for A2 Fire Rated Aluminium Cladding - TFS1 (CWCT Tested)

Clear selection

Latest news & updates for A2 Fire Rated Aluminium Cladding - TFS1 (CWCT Tested)

Project Image update - Premier Inn, Glasgow. We supplied 5000m2 of our CWCT tested TFS1 large format panel system in Interpon PPC, achieving an A2 fire rated performance. #facade #cladding #aluminium #rainscreen
Case Study
Our 4mm TFS1 Through Fix Rainscreen was used for this residential reclad scheme.
Case Study
Baidu
map